The Rohde & Schwarz MXO54-1000 combines four analogue channels and 1 GHz bandwidth within the advanced MXO 5 Series platform. Built around Rohde & Schwarz's next-generation oscilloscope architecture, the instrument delivers exceptional waveform acquisition performance, deep acquisition memory, advanced multispectrum analysis, and industry-leading measurement precision in a compact laboratory instrument. The MXO 5 family spans bandwidths from 350 MHz to 2 GHz for four-channel models and incorporates Rohde & Schwarz's highest-performance oscilloscope technology outside its premium RTP platforms.
At the core of the MXO54-1000 is a true 12-bit analog-to-digital converter operating at full resolution across all sample rates. Compared with conventional 8-bit oscilloscopes, this architecture delivers sixteen times greater vertical resolution, enabling engineers to observe subtle signal variations, power rail ripple, switching artefacts, jitter, transient disturbances, and signal integrity issues with exceptional clarity. HD mode further extends effective vertical resolution to as much as 18 bits while maintaining up to 10-bit ENOB performance.
The oscilloscope supports sampling rates up to 5 GSa/s and provides 500 Mpoints acquisition memory per channel as standard. Optional memory expansion increases capture depth to 1 Gpoint, enabling extremely long recording times while maintaining fine timing resolution. This architecture is particularly valuable for FPGA validation, DDR memory debugging, embedded system development, communications systems testing, protocol analysis, and transient event investigation.
A defining characteristic of the MXO 5 platform is its acquisition performance. The MXO54-1000 captures more than 4.5 million waveforms per second while simultaneously supporting spectrum acquisition rates exceeding 50,000 FFT calculations per second. This dramatically improves the probability of detecting rare glitches, intermittent faults, timing violations, protocol anomalies, and sporadic disturbances that often remain hidden on slower oscilloscope architectures.
The integrated multispectrum analysis system supports up to four simultaneous spectrum displays with independent time-domain and frequency-domain controls. Engineers can analyse EMI emissions, RF activity, harmonics, switching power supplies, clock systems, and mixed-domain interactions without requiring a dedicated spectrum analyzer. Zone triggering is available across analogue, spectrum, and mathematical measurements, enabling highly selective event capture in complex systems.
Advanced digital triggering includes edge, pulse width, runt, glitch, timeout, setup-and-hold, logic, serial bus, zone, spectrum, and math triggering. Trigger sensitivity down to 0.0001 divisions, trigger rearm times below 21 ns, and trigger jitter of approximately 1 ps provide exceptional event isolation and debugging performance for demanding engineering applications.
The large 15.6-inch Full HD capacitive touchscreen provides extensive workspace for simultaneous viewing of waveforms, decoded protocols, FFT measurements, automated measurements, and multiple spectrum displays. The platform supports optional 16-channel logic analysis, arbitrary waveform generation, protocol analysis, power analysis, frequency response analysis, automotive Ethernet analysis, and aerospace communications protocol support.
| Specification | MXO54-1000 |
|---|---|
| Oscilloscope Channels | 4 |
| Bandwidth | 1 GHz |
| Rise Time | Approx. 350 ps |
| Maximum Sample Rate | 5 GSa/s |
| ADC Resolution | 12 Bit |
| HD Resolution Mode | Up to 18 Bit |
| ENOB | Up to 10 Bit |
| Standard Memory Depth | 500 Mpoints per Channel |
| Optional Memory Depth | 1 Gpoint |
| Waveform Capture Rate | > 4,500,000 Waveforms/s |
| FFT Rate | > 50,000 FFT/s |
| Spectrum Displays | Up to 4 Simultaneous |
| Real-Time Signal Visibility | Up to 90% |
| Vertical Sensitivity (50 ohm) | 500 µV/div to 1 V/div |
| Vertical Sensitivity (1 Mohm) | 500 µV/div to 10 V/div |
| Input Impedance | 50 ohm or 1 Mohm |
| Trigger Sensitivity | 0.0001 Div |
| Trigger Rearm Time | < 21 ns |
| Trigger Jitter | ~1 ps |
| Mixed Signal Capability | Optional |
| Digital Channels | Up to 16 |
| Arbitrary Waveform Generator | Optional, 2-Channel 100 MHz |
| Protocol Analysis | Optional |
| Power Analysis | Optional |
| Frequency Response Analysis | Optional |
| Display Size | 15.6 Inch |
| Display Resolution | 1920 × 1080 Full HD |
| Touchscreen | Capacitive Multi-Touch |
| Interfaces | USB Host, USB Device, LAN, HDMI |
| Weight | Approx. 9 kg |
The MXO54-1000 is ideally suited for signal integrity analysis, FPGA validation, DDR memory debugging, high-speed serial bus development, communications engineering, RF troubleshooting, aerospace electronics, automotive electronics, EMI investigations, protocol verification, laboratory research, and advanced electronics engineering applications requiring 1 GHz bandwidth, deep memory acquisition, and industry-leading waveform update performance.